Please click here to view our equipment listings on eBay
___________________
Fully Operational Custom 1/10th Scale EMG (EMRG) Railgun / 700k Amp switched cap pulsed power supplies / This is a fully operational “turn-key” electromagnetic railgun system capable of launching a projectile to well over 3900 feet per second. The system is based on a capacitor-discharge pulse-forming network (PFN). Capacitors are charged to 400V. To fire the gun, the capacitors are discharged into the rails by closing thyristor switches in rapid succession. There are 32 capacitor-thyristor switch modules that can each be individually controlled. The current profile and projectile acceleration is programmable. The system includes an electromechanical loader to inject the projectile (armature) into the barrel at the breech end. It also includes an arc-flash chamber with integrated catch assembly to contain the blast and projectile. A cabinet with power supplies and controls hardware is included. Manuals and safety equipment are also included. From loading to firing – everything is controlled from a remote PC terminal (included). Many more images and details available, please inquire.
Lumenis Pulse 120H with Moses 2.0 Technology Pulsed Medical Holmium Laser / Manufactured 2021-04-28 / Excellent Condition / Additional pictures available upon request
Zeiss Trenion Surgical Visualization System with 3D Display Monitor / Model: Trenion 3D HD / Manufactured 2014 / Additional pictures available upon request
Biodesy Delta Conformational Measuring System / Excellent Condition / 2 Available / (biotechnology, biochemical, biophysical, biomedical instrumentation, drug discovery and development, SHG second harmonic generation platform)
Sold Brainlab Curve 100 Dual Display Image Guided Surgical Navigation System / Manufactured July 2014 / Cranial Software, General Software, Spine Software, Spine & Trauma Software
Coherent Monaco Ultrashort Pulse Scientific Laser System / Model Monaco 517-20-1-FS / Manufactured December 2016 / Rated 20 watts output @ 517 nm / The standard pulse width of Monaco is <350 fs for all wavelengths. This pulse width is user-adjustable to >10 ps in the IR
Coherent Vitesse 5W Scientific Laser System / Manufactured November 2016
Coherent Verdi-V18 Scientific Laser System / Pump laser / Model Verdi-18W / Manufactured December 2006
Coherent G-Series Verdi Scientific Research Laser System / Model Verdi G7 / Manufactured June 2011 / Rated 7 Watts @ 532 nm / Powers up, passes all self tests, output measured / Requires 100-240 V, 50/60 Hz / Excellent condition
Sold Coherent RegA 9000 Scientific Research Laser System / Manufactured November 1994
Coherent Mantis Scientific Research Laser System / Manufactured 2008
Sold Lumenis Pulse 30H Pulsed Holmium Medical/Surgical Laser / Model Pulse 30H / Manufactured August 2016 / Specifications: Average Power: 30 Watts, Laser Source: Holmium:YAG, Wavelength: 2.1 µm, Energy per Pulse: 0.2-5 Joules, Repetition Rate: 3-25 Hertz / Powers up and passes all self tests / Includes foot switch / Additional pictures of system available upon request
Lumenis VersaPulse P20 Holmium Medical/Surgical Laser / Manufactured December 2011 / Includes inspection scope, manual, foot switch / Excellent condition / Additional pictures of system available upon request
Lumenis VersaPulse PowerSuite 100 Watt Pulsed Holmium Medical Laser System / Model PowerSuite-100W / Ho:YAG / Excellent condition
Sold Candela VBeam Perfecta 595 nm Pulsed Dye Cosmetic/Medical Laser System / Manufactured March 2006 / Model VBeam Perfecta / Requires 220 volt, single-phase power / Includes laser system and deliver device only / Does NOT include sliders or foot switch
Candela Alex TriVantage Medical Laser System / Manufactured June 2007 / Model Alex TriVantage / Requires 220 volt, single-phase power / Includes laser system and delivery device only / Does NOT include foot switch
Dornier Medilas H 20 DUR-HL20 Holmium Medical Laser System / Manufactured December 2010
Dornier MedTech Medilas D FlexiPulse D60 Medical Laser System / Manufactured February 2009
Big Sky/Quantel Q-switched Pulsed YAG Scientific Research Laser System / frequency doubled to 532nm, 6 month warranty-Big Sky/Quantel oscillator/amplifier rated 125mj/pulse @ 532nm, or 250mj/pulse @ 1064nm, @ 6ns. Pulse rate default rate at 28 Hz, adjustable .01 to 56 Hz rep-rate in .01 Hz steps. This laser is capable of external triggering lamp and/or external triggering of Q-switch, as well as internal triggering, along with adjustable Q-switch delay. Power adjustable to over 200 mj/pulse @ 532nm or over 400mj/pulse @ 1064nm. System is computer controlled by RS-232 or RS-485 format, and all parameter changes are controlled by the computer. Uses Tera-Term freeware, or customized Windows software available from us at no change. Power supply is similar in size to a computer tower and runs on 120V, or 220V, single phase, partially self diagnostic. Voltage selection is automatic switching. Laser is in excellent condition, and comes with manual and 6 month warranty. Picture is at 10Hz Rep rate. Additional 50 million shot, new lamps are available for purchase. Over 125 systems available, and over 175 systems sold. They are very reliable systems, and if for any reason something fails, we can ship a replacement head or power supply within 1 day or ship repair parts. Original acquisition cost nearly $100,000 US. We ship foreign. We have many of these in foreign countries. University purchase orders welcome. We accept checks, purchase orders. No Paypal over $1000. We test and ship within 1 working day of purchase. They are shipped in our custom made boxes. Videos and more pictures available. If any questions please feel free to call or email at any time.
Quantel Opotek Brilliant B Scientific Research Laser System / Model Vibrant B 532 I / Manufactured January 2003
SPI JK200FL Laser Welder / Requires 100-240V, 50/60Hz, Single Phase power
Continuum Precision II 9010 Scientific Research Laser System / Tested, fully operational
Light Age 101 PAL Alexandrite Scientific Research Laser System
Laserscope Aura XP with Star Pulse Medical Laser System / Model Aura XP / Rated 15 watts @ 532 nm / Powers up and passes all self tests / Service/PM visit recommended, the output power was measured just over 16.5 watts when set to 15 watts / Requires 230 V, Single Phase, 50/60 cycle power / Includes footswitch
Laserscope Aura XP with Star Pulse Medical Laser System / Model Aura XP / Manufactured 2013 / Rated 15 watts @ 532 nm / Powers up and passes all self tests / Service/PM visit recommended, the output power was measured at 14.7 watts when set to 15 watts / Requires 120 V, 16 A, 50/60 cycle power / Includes footswitch
Laserscope Aura XP with Star Pulse Medical Laser System / Model Aura XP / Manufactured 2015 / Rated 15 watts @ 532 nm / Powers up / Service/PM visit recommended / Requires 120 V, 16 A, 50/60 cycle power / Includes footswitch
Coherent Verdi-V18 Scientific Laser System / Pump laser / Model Verdi 18W / Manufactured August 2008
Coherent Tunable, Modelocked, Femtosecond Ultrafast Ti:Sapphire Scientific Laser System / Model Chameleon / More details to follow
Lumenis VersaPulse PowerSuite 100 Watt Pulsed Medical Holmium Laser System / Model PowerSuite-100W / Ho:YAG / Powers up and passes all self tests, no further testing / Includes interlock, footswitch / 200/208/230V, 50/60Hz, 30A, single phase power required / Rated 100 Watt @ 2100 nm / Many additional pictures available upon request, including the Energy Calibration Plot / Urology, HoLEP, BPH Treatment
Dornier MedTech Medilas H Solvo H30 Pulsed Medical Holmium Laser System / 30 Watts
Laserscope/AMS GreenLight XPS Medical Laser System / Manufactured 2/2011 / 1598 hours of use / System powers up and passes all self tests
Laserscope/AMS GreenLight XPS Medical Laser System / Manufactured 10/2011 / 860 hours of use / System powers up and passes all self tests
Dornier Medilas H 20 DUR-HL20 Holmium Medical Laser System
Convergent Energy Gemini Industrial CO2 Laser Cutting Systems / 2 available / Coherent Diamond CO2 lasers /
Sold Quanta System Litho 30W Holmium Medical Laser System / Manufactured 11/2015
Convergent Laser Technologies Pulsed Medical Holmium Laser System / Model Odyssey 30B / Manufactured July 2011 / Rated 30 watts
Convergent Laser Technologies Pulsed Medical Holmium Laser System / Model Odyssey 30B / Manufactured February 2009 / Rated 30 watts
American Medical Systems (AMS)/Laserscope Medical Laser System / Model Aura XP with Star Pulse / Manufactured 6/2012 / 178 Total System hours / Rated 15 watt @ 532 nm / Includes cart and foot switch / Fiber and power meter are NOT included
Covidien superDimension Navigation System / Manufactured 2014
Covidien superDimension Navigation System / InReach / Reference #: AAS00161-20R / Manufactured August 2013 / Runs on Windows Embedded 7 / Includes superDimension Patient Sensor Triplet Reference #: AAS00180-01 and manuals
Beamer Fiber Laser Marking System / Model FB22 / Manufactured 2015 / Many additional pictures and video clip of system in operation available upon request / Marker, Engraver, Etcher
Thermi RF Arvati T50RF Radio Frequency Skin Rejuvenation Medical Device / Manufactured 2019
Cook Medical / Convergent Laser Technologies Pulsed Medical Holmium Laser System / Model Odyssey 30B / Manufactured April 2013 / Rated 30 watts
Spectra-Physics Quanta-Ray Pulsed Nd:YAG Scientific Laser System / Model INDI-HG / Manufactured September 2007 / 10 Hz rep rate / Rated 450 mJ/pulse with 5-8 ns pulse width at 1064 nm / Tested operational / 208-240V, single phase power required
NinePoint NvisionVLE Imaging Endoscopic Esophageal Pancreatic Barrett OCT Medical Laser System / Nvision VLE (Volumetric Laser Endomicroscopy) Imaging System / Powers up and passes all self tests, no further testing / Includes footswitch / 100-240 VAC, 6.0 A, 50-60Hz power required
Sold Fotona Lightwalker AT S Dental Laser System / Model M021-5AF/1 S / Manufactured April 2019 / Er:YAG & Nd:YAG – 2940 & 1064 nm / Powers up and passes all self tests / Includes key and foot switch / Does NOT include any handpieces
AMS Laserscope GreenLight XPS Prostate Medical Laser System / Rated 180 Watts @ 532 nm / Manufactured September 2011 / Less than 340 hours of use / BPH Treatment
Sold IPG Photonics Corp YLS-4000 4kW Output Ytterbium Industrial Laser Source / Model YLS-4000-S1T / Rated 4000 watts @ 1070 nm / Manufactured February 2014 / Requires 400/480 VAC, 3 Phase, 50-60Hz power / Recently removed from a working manufacturing facility / Cutting, Welding, Drilling
Cynosure SculpSure Lipolysis Medical Laser Systems / Systems manufactured in 2017 and 2016 / 1060 nm output / Requires 200-240 Volt, Single-phase, 50/60Hz power / System powers up and passes all self tests
Lumenis VersaPulse PowerSuite 100 Watt Pulsed Medical Holmium Laser Systems / Model PowerSuite-100W / Ho:YAG / Powers up and passes all self tests, no further testing / Includes interlock, footswitch / 200/208/230V, 50/60Hz, 30A, single phase power required / Rated 100 Watt @ 2100 nm / Many additional pictures available upon request, including the Energy Calibration Plot / Urology, HoLEP, BPH Treatment
Coherent Lumenis VersaPulse PowerSuite Pulsed Medical/Surgical Holmium Laser / Model PowerSuite-20 / Manufactured November 2008 / Rated 20 watts / 2100 nm / Powers up and passes all self tests / Includes foot switch
(3) Candela Vbeam Perfecta Pulsed Cosmetic Medical Surgical Dye Laser Systems / Manufactured 2018 / Less than 20,000 pulses / 595 nm / Requires 220 volt, single-phase power / Powers up, no further testing / Includes laser system and sliders pictured / Does NOT include delivery device or foot switch
Sold Thermo Scientific LTQ Orbitrap Velos Pro Mass Spectrometer with ETD Laboratory Equipment / Very well taken care of! / Too many consumables, spares, extras to list! / Recently removed from working lab environment / Includes manuals, software, vacuum pumps, chiller, cables, etc.
Lumenis AcuPulse 40 Watt Medical CO2 Laser System / Less than 3 hours tube work time! / Powers up, output measured! / Manufactured October 2016 / Power: 100-240V, 50-60Hz / Includes laser system and foot switch
Sold Lutronic Denta 2 CO2 Dental Laser System / Rated 30 Watts / Powers up, output measured! / Manufactured 2014 / Power: 100-120V, 50-60Hz / Includes laser system, foot switch, and accessories
Coherent Infinity Tunable Scientific Nanosecond Pulsed Nd:YAG Laser System / Q-switched pulsed YAG laser Rated: 0.1-50 Hz rep rate: 500 mj/pulse at 1064 nm 250 mj/pulse at 532 nm Pulse width of 3.5 ns at 1064 nm, and 3 ns at 532 nm 50-100 Hz rep rate: 400 mj/pulse at 1064 nm 200 mj/pulse at 532 nm Divergence, full angle: < 9.7 mrad Line width: single longitudinal mode < 2x transform limit due to diode pumped injection seeded oscillator Single shot: < 250 MHz Timing jitter: < 500 psec SBS cell (phase conjugate mirror) for wave front phase correction Output beam size: 5.5mm Includes manual (digital). SHG currently installed. XPO (OPO) with controller available at additional cost. Image shows the system producing 20 watts 532 nm @ 100 Hz and 3.73 watts 532 nm @ 10 Hz. Power meter is NOT included with sale
Sold Coherent Verdi V5 pump Laser with FemtoLaser Femtosource Compact Ultrafast Ti:Sapphire Scientific Laser System / Part of an optical coherence tomography (OCT) system?
Dornier Medilas H 20 DUR-HL20 Holmium Medical Laser System
Continuum 9010 Precision II Scientific Laser System with Seed Laser
Continuum 7010 Powerlite Scientific Laser System
Sold Miyachi Unitek Fiber Laser Marking System / Model LMF2000 / Rated 20 Watts / 6″ marking field / Windows based WinLase software / Includes enclosure with two bays / Requires 110 volt 50-60Hz power / Many additional pictures and video clip of system in operation available upon request / Marker, Engraver, Etcher
(2) Telesis Model 6 FQ 50 Fiber Laser Marker / Engraver / Etcher Systems
Spectra Physics GCR-290 Scientific Laser System
Sold Continuum Tunable Pulsed Nd:YAG OPO Scientific Laser System / Model Horizon / Surelite SL EX
Sold Thermo KeyTek ECAT ESD EFT SURGE PQF Test Set Electronic Equipment / Includes E506-4W surge network, E509A surge network, and E515 surge network modules / Includes laptop / Unit is in very good condition
(2) JK Lumonics 702H Industrial Laser Systems / Many JK Lumonics 700 Series laser system parts available
Zeiss IntraBeam PRS500 Laboratory Research System / Very well taken care of! / Includes 8 spherical applicators, manuals, controllers, ion chamber, dosemeter, etc. / We have many more images available upon request
Candela Vbeam Perfecta 595 nm Pulsed Dye Cosmetic / Medical Laser System / Manufactured 2018 / Less than 20,000 pulses! / Requires 220 volt, single-phase power / Brand new head kit / Powers up, no further testing / Includes laser system and sliders pictured / Does NOT include delivery device or foot switch / Additional pictures available upon request
Lumenis VersaPulse PowerSuite 100 Watt Pulsed Medical Holmium Laser System / Model PowerSuite-100W / Ho:YAG / Powers up and passes all self tests, no further testing / Includes interlock / Does NOT include footswitch / 200/208/230V, 50/60Hz, 30A, single phase power required / Rated 100 Watt @ 2100 nm / Many additional pictures available upon request, including the Energy Calibration Plot / Urology, HoLEP, BPH Treatment
Sold Candela Pulsed Medical/Surgical Dye Laser / Model Vbeam, V beam / Manufactured October 2001 / 595nm output / Requires 230 Volt, Single-phase, 50/60Hz power / System lases but will most likely need a new dye kit
Continuum Surelite SLI-10 Scientific Laser System
Sold Matrix Integrated Systems / System Ten / Model 1107 / Through the wall Reactive Ion Etcher / Plasma Asher / 6″ or 8″ Wafer Capability / Includes vacuum pump stack, chillers, manual, and software / Guaranteed working / Many additional pictures available upon request
American Electronic Laboratories-1180 Frequency Converter Test Equipment / ATTR-2193 receiver combination / ATTR-2193 Tempest qualified receiver in excellent working order, and calibrated. The A.E.L. 1180 frequency converter increases receiver’s range to 18 GHz controlled by fiber optic by the receiver. This wide band receiver qualifies for EAR 5A980 by the U.S. State Department and can not be exported from the continental U.S. As can be seen from the photo, the narrowest bandwidth is 200 Hz. IF and Video bandwidths range from 200 MHz to 200 Hz. Maintenance and operation manual included. Units are in excellent condition. 3 receivers, 2 1180’s available.
Light Age Inc. Pulsed Alexandrite Scientific Laser System / Model 101 PAL / 720 nm – 800 nm / Incomplete / Untested / Additional pictures available upon request
Sold IPG 1 kW CNC Fiber Industrial Laser Welding System / Haas Mini Mill CNC Vertical Milling Machine equipped with X, Y, Z, and rotary stages / Manufactured December 2006 / Requires 240V, 60Hz, 15A / Includes 1000 Watt IPG Photonics Fiber Laser / Model YLR-1000-IC / Requires 480 VAC, 3 PH, 60Hz / Manufactured December 2006 / Includes Riedel PC 41.02-KE-S Chiller / Currently set up as a laser welder / Additional pictures available upon request / Fully operational / Used for prototyping only, low hours of use
Sold Parr Instrument Model 4525 Bench Top Reactor Scientific Equipment / Includes Model 4848 controller / Includes manual and spare parts pictured / Appears to be unused / Additional pictures available upon request
Sold Spectra Physics 20 Watt Q-switched DPSS UV 355 nm Scientific Research Laser System / Model Talon-355-20 / Manufactured 2015 / In like new condition with 0 hours of use / 110 Volt required / *Note: Laptop, lab jacks, power meter, and chiller are NOT included
Sold ARGES 5-Axis 3D Laser Scan Head Scientific Laser System / Model Precession Elephant / Includes ASC2 Controller, software, and PC interface card / Configured for a 355 nm laser system / Never used, in like new condition / 110 Volt required
Sold Spectra Physics 15 Watt Q-switched DPSS UV 355 nm Scientific Laser System / Model Talon-355-15 / Manufactured 2015 / In like new condition with less than 8 hours of use / Tested, operational / 110 Volt required / *Note: Laptop, lab jacks, power meter / head and chiller are NOT included
Zeiss LSM 510 META VIS/NLO Multiphoton Laser Scanning Microscope / Includes tested working Coherent Chameleon Tunable Femtosecond Ultrafast Scientific Laser System / Axiovert 200 M / *Note: Computer / software included, Optical table and power meter not included / More information / specs. available upon request
*INSTALLATION, TRAINING, AND WARRANTY AVAILABLE!* (at an additional cost)
Coherent AVIA Q-switched, DPSS, UV 355 nm Scientific Laser System / Rated 23 Watts / Model AVIA 355-23-250 / Manufactured December 2009 / 110 Volt required / *Note: Chiller is NOT included
Coherent 10 Watt Q-switched DPSS UV 355 nm Scientific Laser System / Model AVIA 355-X / 11 Zero Hour positions on the 36 position crystal / Manufactured April 2006 / Tested, operational / 110 Volt required
Lumenis VersaPulse PowerSuite 100 Watt Medical Holmium Laser System / Model PowerSuite-100W / 2100 nm / Ho:YAG / Manufactured March 2006 / Powers up and passes all self tests / Includes interlock, foot switch / 200/208/230V, 50/60Hz, 30A, single phase power required / Urology, HoLEP, BPH Treatment
Spectra Physics Mai Tai DeepSee Scientific Laser System / Manufactured July 2011 / Tunable from 690 nm to 1040 nm / Dispersion compensation
Coherent Tunable, Modelocked, Ultrafast Ti:Sapphire Scientific Laser System / Model Chameleon / Manufactured September 2005 / Verdi V12 pump laser / Automated Wavelength Tuning from 705 nm to 980 nm / Less than 555 hours use on head and both diodes / 100 to 250 VAC, 50/60Hz power required
Coherent/APE Chameleon Compact Optical Parametric Oscillator (OPO) for femtosecond & picosecond Ti:Sapphire laser pumping / Many additional pictures available upon request
Coherent Tunable Modelocked Ti:Sapphire Ultrafast Scientific Laser System / Includes Coherent Verdi V8 model Verdi 8W / Manufactured December 2002 / Less than 2300 hours on the diodes / Mira model 900 with 900 controller / Verdi laser diodes are good but system is not lasing due to LBO temperature fault holding the system back. We believe the LBO has a bad thermistor, more info upon request / No further testing has been done
JK Industrial Fiber Laser Welding System / Includes System 5000 Work Station with JK2000FL 2000 Watt fiber laser source / Manufactured 2014 / 1080 nm output / Currently setup for welding, capable of cutting and drilling / Equipped with Aerotech PRO165 X and Y axis stages and an Aerotech PRO115 Z axis stage with A3200 drivers / System is in new / unused condition
Lumonics 700 Series Pulsed Nd:YAG Industrial Laser System / Model JK 702H / Rated 350 Watts / 1064 nm / Cutting, Welding, Drilling / Please contact us if you need only a certain component. We will part out or sell the entire system.
Spectra Physics Mai Tai Ultrafast Scientific Laser System / Femtosecond single-box Ti:Sapphire oscillator, 10 W Millennia pumped, with automated wideband wavelength tuning from 710 to 950 nm, pulse width < 80 fs / System is in excellent condition with less than 840 hours of use on the head
Spectra-Physics Quanta-Ray Pulsed Nd:YAG Scientific Laser System / Model PRO-230 / 1064 nm and 532 nm operation / Manufactured May 2001 / Rated 1250 mJ/pulse @ 1064 nm, 650 mJ/pulse @ 532 nm / 8-12 ns pulse width at 1064 nm, 6-10 ns pulse width at 532 nm / 220/240 V, single phase power required
Injection Seeded Spectra-Physics Quanta-Ray GCR-230 Pulsed Nd:YAG Scientific Laser System / 10 Hz rep rate / Rated 1250 mJ/pulse with 8-12 ns pulse width at 1064 nm / Tested operational, measured 12.5 watts average / Oscilloscope and power meter not included / 208-240V, single phase power required
Sold Unused Seeder/Seed Laser for Spectra-Physics Quanta-Ray GCR Lab Pro Series Nd:YAG Scientific Laser Systems / Model 6350-1
Coherent Infinity Tunable Scientific Nanosecond Pulsed Nd:YAG Laser System / Q-switched pulsed YAG laser Rating: 0.1-50 Hz rep rate: 500 mj/pulse at 1064 nm 250 mj/pulse at 532 nm, Pulse width of 3.5 ns at 1064 nm and 3 ns at 532 nm, 50-100 Hz rep rate: 400 mj/pulse at 1064 nm 200 mj/pulse at 532 nm, Divergence, full angle: < 9.7 mrad, Line width: single longitudinal mode < 2x transform limit due to diode pumped injection seeded oscillator, Single shot: < 250 MHz, Timing jitter: < 500 psec SBS cell (phase conjugate mirror) for wave front phase correction, Output beam size: 5.5mm / XPO Type II (OPO) currently installed / Tuning Range – Signal: 420 to 650 nm, Idler: 2200 to 1000 nm / Includes digital manual / Additional pictures available upon request
Sold Coherent Ti:Sapphire Ring Dye Scientific Laser / Model 899
FEI XL 30 SEM Scanning Electron Microscope EDAX EDS Shipping Damage Parts System / System suffered damage during shipping / Includes computer with software / Additional pictures available upon request
Sold Nanometrics NANOSPEC 9000I 7000-0593 Wafer Integrated Film Analysis System / Nanometrics NANOSPEC 9000I 7000-0583 / Nanometrics NANOSPEC 9000I / Nanometrics NANOSPEC 9000I 7000-0560 / Additional pictures available upon request
Telesis Fiber Laser Marking / Engraving System / Model Zenith 10F / Windows XP based Merlin II LS Visual Design Software / Manufactured August 2006 / 163 mm lens with 4.33″ X 4.33″ marking field / Air-cooled / 10 Watt fiber laser / 110 volt operation / Includes enclosure with manual Z-axis bedplate and red pilot / pointer laser / System powers up and was able to mark / engrave metal running a test program
Laservall Beamer Ultra-Dex Laser Marking / Engraving System / Model Violino / Windows XP based Laservall Smartist version 4.1 software / Air-cooled / Diode pumped solid state laser / Q-switched Nd:YAG / 1064 nm / 4.3 inch marking field / 110 volt operation / Includes enclosure with motorized Z-axis and red pilot / pointer laser / We believe this is a 10 watt system / System powered up and was able to mark / engrave metal running a test program
Synrad FireStar Industrial CO2 Laser Tube Cutting System / Model FSF400SB / Manufactured September 2006 / Rated 400 Watts / 230 Volt, 3 Phase
Coherent Libra One-Box, High-Energy, Ti:Sapphire, Femtosecond, Regenerative Amplifier Scientific Laser System / Manufactured 2006 / System consists of: Evolution pump laser, regenerative amplifier, stretcher and compressor / System is not complete as the Vitesse 2W laser has been removed (see images) / Includes laser controllers / power supplies, high voltage power supply, cables, synchronization and delay generator (SDG), Lytron chiller / System is being sold in as-is, where-is, untested condition.
Spectra-Physics Hurricane Diode Pumped Kilohertz Ti:Sapphire Regenerative Amplifier Scientific Laser System / 1 KHz rep rate / pulse < 130 fs / energy at 1 KHz >750 µJ / Wavelength range: 780-820 nm
Sold Coherent MIRA 900 Controller / Part number: 0163-709-00 / Powers up, no further testing has been done
CLC Control Laser Corp. Icon / Insignia LX-900 Maxwell Power Supply For Nd:YAG Laser Marking / Engraving System / See picture for model number / 220 Volt, Single Phase, 50/60Hz power required / Tested operational
CLC Control Laser Corp. Icon / Insignia LX-900 RF Driver For Nd:YAG Marking / Engraving System / Part number: 228692 / Tested operational
Lee Laser Nd:YAG Pump Chamber / Head Assembly / Model 120641-001 / Includes Rod, Lamp and Reflectors / Looks like it may be new old stock, can’t be sure
Lee Laser Autocollimator for Nd:YAG Laser Alignment / Part number: 010187-001 / 120V / Working condition
Continuum Pulsed Nd:YAG Scientific Laser System / Model Powerlite 7010 / 1064 nm, 532 nm, and 355 nm operation / Manufactured 2001 / Single lamp, twin rod (oscillator, amplifier) pump chamber / Rated 850 mJ/pulse @ 1064 nm, 400 @ 532 nm, and 200 @ 355 nm / 6-8 ns pulse width at 1064 nm, 5-7 ns pulse width at both 532 nm and 355 nm / 220/240V, single phase power required / Fundamental has been measured just under spec. (possibly needs tuned)
Continuum Pulsed Nd:YAG Scientific Laser System / Model Surelite SLI-20 / 1064 & 532 nm output / Manufactured August 2012 / Rated 420 mJ/pulse @ 1064 nm (we measured over 8.5 watts average power) at 20 Hz rep rate with a 5-7 ns pulse width / Rated 160 mJ/pulse @ 532 nm (we measured almost 3.5 watts average power) at 20 Hz rep rate with a 4-6 ns pulse width
Continuum Surelite II Pulsed Nd:YAG Scientific Laser System / Model SLII-10 / Producing factory spec. power at 1064 nm and 532 nm / 355 and 266 nm harmonics available for an additional charge / Manufactured February 1998 / Rated 650 mJ/pulse @ 1064 nm, 300 @ 532 nm / 5-7 ns pulse width at 1064nm, 4-6 ns pulse width at 532 nm / Tested operational / 208-240V, single phase power required
Continuum Surelite Pulsed Nd:YAG Scientific Laser System / Model SLI-10 / 1064 nm, 532 nm, 355 nm and 266 nm operation / Manufactured September 2006 / Rated 450 mJ/pulse @ 1064 nm, 200 @ 532 nm, 65/100 @ 355 nm, and 60 @ 266 nm / 5-7 ns pulse width at 1064 nm, 4-6 ns pulse width at 532 nm, 355 nm, and 266 nm / Tested operational / 208-240V, single phase power required
Continuum Pulsed Nd:YAG Scientific Laser System / Model Surelite / 1064 & 532 nm output / 30 Hz
Sold Applied Materials/Applied Baccini UV Laser Edge Deletion / Isolation System for crystalline silicon photovoltaic cell production
Cook Medical / Convergent Laser Technologies Pulsed Medical Holmium Laser System / Model Odyssey 30B / Manufactured June 2013 / Rated 30 watts
Dornier MedTech Medilas H Solvo H30 Pulsed Medical Holmium Laser System / 30 Watts
Dornier Pulsed Medical Holmium Laser System / Model Medilas H / Manufactured December 2008 / Rated 20 Watt @ 2100 nm / Passes all self tests / A video of the system in operation is available / Includes foot switch / Additional pictures available upon request
Dornier MedTech Pulsed Medical Holmium Laser System / Model Medilas H20 / Manufactured September 2006 / Rated 20 watts @ 2100 nm
Coherent Verdi Scientific Laser System / Model Verdi-5W / Manufactured 2005 / 5 watts @ 532 nm / Tested operational
Elight Q-switched Ti:Sapphire LIDAR Pulsed Nd:YAG Laser System / model Titania / tunable 690-960 nm / >400 mJ/pulse / 20 Hz max rep rate / From the manual: Laser rod: 6 mm x 100 mm, 0.10 wt% Ti2O3, UC 141V / Power requirements: 3 phase, 208V, 50/60Hz / Untested
Ophir Photonics 5KW Power Meter Head
Ophir Photonics / Spiricon ModeCheck Beam Analyzer for CO2 Lasers
Sold J.A. WOOLLAM Spectroscopic Ellipsometer / Includes these components: EC-270, M-44, INP-500, LPS-400, and ST-260/ Additional pictures available upon request
AMS Laserscope OR Boston Scientific GreenLight MoXy Laser Fiber + Fiber Card / Model 0010-2400 / Liquid cooled
2008 FARO X Laser Tracker / Head only / Incomplete, unable to test
All equipment listed is subject to prior sale and availability. All information provided is believed to be accurate but Cleveland Laser Solutions, Inc. is not responsible for any errors, changes, or misrepresentations which may arise.